Drop Down Menu

Westline Direct On Line Starters to 355kW

Features

  • Complies with IEC947 BSEN60947 Type 2 Short Circuit Co-ordination
  • Robust, all welded steel enclosure, up to IP55 protection (* Note 1)
  • Hinged front cover with positive door catches
  • Removable component baseplate
  • Front cover and gland plates bonded to enclosure main earth
  • Wide range of accessories
  • On load isolator or Fused combination switch
  • Switch handle lockable in OFF position which also locks front cover
  • Switch has positive internal indication of contact position (optional)
  • 'R' Type Thermal Overload protection with interchangeable heaters
  • Incorporates well proven Westmaster Contactors
  • Control circuit fuses as standard
  • Standard paint finish : Case - Graphite Grey RAL 7024, Door - Agate Grey RAL 7038

Note 1 : Starters to size WPD are wall mounted and have protection to IP55. Starters above this size are floor mounting and have protection to IP51 as standard, with the facility to be made to IP55 if required.

 

Max. Rated Insulation Voltage :
Ambient Temperature Operating Limits :
Ambient Temperature Storage Limits :
Altitude :
Relative Humidity (IEC68-2) :
Supply Voltage Operating Limits :
Short Circuit Co-ordination

660V
-50C to +450C (* Note1)
-200C to +650C
Up to 2000M
95% at 400C
85% to 110%
50kA prospective current

Type C to BS4941
Type 2 to IEC947, BS EN ISO60947

Note 1 : Up to +650C derated.

 

Max FLC

Approximate kW / HP

Ordering Code
220V
415/440V
HP
kW
HP
kW
   22        7.5        5.5      15      11    WED00*B  
   37      10        7.5      25      18.5    WGD00*B  
   44      15      11      30      22    WHD00*B  
   60      20      15      40      30    WJD00*B  
   72      25      18.5      50      37    WKD00*B  
 105      40      30      75      55    WMD00*B  
 138      54      40    100      75    WND00*B  
 170      70      52    125      90    WPD00*B  
 245    100      75    180    132    WRD00*B  
 330    136    100    250    184    WTD00*B  
 600    250    184    474    355    WYD00*B  

To complete Ordering Code, replace the * with :

O - No Isolator Required
L - Fitted with Isolator
S - Fitted with Fuse Switch

Order details to include starter type together with supply details and motor rating.
Optional extras by full description.
Heater elements for the 'R' type thermal overload to be ordered separately.

 Starter Type    Mounting
 A  
 B  
 C  
 D  
 E  
 Ø F
 M
(When filted) 
 Case
 Ref  
 WEDOOOB     Wall      400      250      174      300      150      9     223     B1   
 WEDOOLB 
 WGDOOOB
 WHDOOOB  
 WEDOOSB     Wall      500      250      174      400      150      9     223     B2   
 WGDOOLB
 WHDOOLB
 WJDOOOB  
 WGDOOSB    Wall      550      350      174      450      250      9     223     B3   
 WHDOOSB  
 WJDOOLB  
 WKDOOOB  Wall    566    350    222    450    250     9      B4  
 WMDOOOB
 WKDOOLB  Wall    666    350    222    550    250    11    271    B5  
 WMDOOLB
 WJDOOSB    Wall      666      450      222      550      350     11     271     B6   
 WKDOOSB  
 WMDOOSB  
 WNDOOOB  Wall    766    450    222    650    350    11      B7  
 WPDOOOB
 WNDOOSB     Wall     1116     500     222     1000     400    11    271    B8  
 WPDOOSB  
 WNDOOLB
 WPDOOLB

 Starter Type    Mounting
 A  
 B  
 C  
 D  
 E  
 WRD/WTD    Floor 1257 525 368 575 275
 WRD/WTD (Isol. / Fused Switch)    Floor 1432 525 368 575 275

Approximate Shipping Specification

 Starter Type  
 Nett Kg
Gross Kg
Cu. M
 WRD/WTD    118 147 0.63
 WRD/WTD (Isol. / Fused Switch)    140 175 0.71

Diagram Ref : BS5007135P1 - Typical sizes WED, WGD & WHD

Diagram Ref : BS5007135P2 - Typical sizes WJD & WKD

Diagram Ref : AS5006272 - Typical sizes WMD, WND, WPD, WRD & WTD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terms & Conditions | Privacy | Help | Sitemap
© 2016 Whippendell Marine Ltd.